195 research outputs found

    Simulation support for performance assessment of building components

    Get PDF
    The determination of performance metrics for novel building components requires that the tests are conducted in the outdoor environment. It is usually difficult to do this when the components are located in a full-scale building because of the difficulty in controlling the experiments. Test cells allow the components to be tested in realistic, but controlled, conditions. High-quality outdoor experiments and identification analysis methods can be used to determine key parameters that quantify performance. This is important for achieving standardised metrics that characterise the building component of interest, whether it is a passive solar component such as a ventilated window, or an active component such as a hybrid photovoltaic module. However, such testing and analysis does not determine how the building component will perform when placed in a real building in a particular location and climate. For this, it is necessary to model the whole building with and without the building component of interest. A procedure has been developed, and applied within several major European projects, that consists of calibrating a simulation model with high-quality data from the outdoor tests and then applying scaling and replication to one or more buildings and locations to determine performance in practice of building components. This paper sets out the methodology that has been developed and applied in these European projects. A case study is included demonstrating its application to the performance evaluation of hybrid photovoltaic modules

    Modelling of double ventilated facades according to CEN Standard 13790 method and detailed simulation

    Get PDF
    The European Energy Performance of Buildings Directive (EPBD) encourages the use of technologies in buildings that can potentially improve their energy performance. Double ventilated façades can often have a positive contribution to this objective and their effect has to be quantified during the calculation of the overall energy performance of the buildings. The updated EN ISO 13790 Standard is part of the new set of CEN Standards that have to be delivered to support the EPBD requirement for a general framework for the methodology of calculation of the total energy performance of buildings. It contains a method to calculate the contribution of the double ventilated façades to the annual heating and cooling requirements of buildings. At the same time (validated) detailed simulation tools, which are also allowed in this Standard, offer an alternative way to quantify the effect of the double ventilated façades on the buildings' energy performance. This paper examines a case study where the ESP-r simulation program and the method described in the Standard were used for a common building specification to investigate the impacts from a double ventilated façade on the energy performance of the building. It discusses the potential differences that might appear when a detailed simulation tool (ESP-r) is used with constrained (according to the Standard) inputs and also unconstrained inputs, compared to the outputs obtained from the method described in the Standard. Some parametric studies are included to show whether the same trends are obtained using both the method in the Standard and the detailed simulation approach

    An integrated approach to indoor contaminant modelling

    Get PDF
    Air pollutants are those chemicals that are not generally present in the atmosphere because of natural causes but are disseminated into the air by human activity. In most parts of Europe, outdoor pollutants are principally the products of combustion from space heating, power generation, chemical industry waste, or from motor vehicle traffic (McGinlay 1997). Indoor air environments contain a myriad of inorganic and organic gases and vapors typically in trace (parts-per-billion) quantities. The chemical composition of air varies widely between particular locations as well as between measurements taken at different times for the same location. The nature of these variations is such that it is difficult to definitively characterize a typical indoor air environment with respect to specific contaminants present and concentration levels. A large number of air pollutants have known or suspected harmful effects that can be manifested on plant or animal life and/or the environment. Pollutants may not only prove a problem in the immediate vicinity of their emission, but they can travel long distances and react with other species present in the atmosphere to produce secondary pollutants (Weschler 2004)

    An engineering approach to modelling of dynamic insulation using ESP-r

    Get PDF
    The use of Dynamic Insulation (DI) can enable recovery of conduction heat loss through a building envelope. This is an active process that allows air to move through the fabric against the temperature gradient. Additionally it promises better indoor air quality, primarily due to filtration properties of the construction material [11]. This paper is concerned with quantifying the energy savings and enhancement of human comfort if this technology is integrated into a building. To ascertain the impact of the technology on whole-building performance, it is necessary to undertake detailed dynamic modelling. A suitable building and plant simulation computer tool (ESP-r) was employed to do this. A technique for modelling the dynamic insulation was developed and validated against known analytical solutions. A full-size test house was then simulated, in the UK climate, with and without DI. Comparative results show that better thermal comfort and energy savings are possible with the use of DI. The results obtained have been translated into suggestions for best practice

    History and development of validation with the ESP-r simulation program

    Get PDF
    It is well recognised that validation of dynamic building simulation programs is a long-term complex task. There have been many large national and international efforts that have led to a well-established validation methodology comprising analytical, inter-program comparison and empirical validation elements, and a significant number of tests have been developed. As simulation usage increases, driven by such initiatives as the European Energy Performance of Buildings Directive, such tests are starting to be incorporated into national and international standards. Although many program developers have run many of the developed tests, there does not appear to have been a systematic attempt to incorporate such tests into routine operation of the simulation programs. This paper reports work undertaken to address this deficiency. The paper summarizes the tests that have been applied to the simulation program ESP-r. These tests have been developed within International Energy Agency Annexes, within CEN standards, within various large-scale national projects, and by the UK's Chartered Institution of Building Services Engineers. The structure used to encapsulate the tests allows developers to ensure that recent code modifications have not resulted in unforeseen impacts on program predictions, and allows users to check for themselves against benchmarks

    On-line energy services for smart homes

    Get PDF
    The EC funded 'Smart Homes' project commenced in 2001 as a 3 year programme. The primary objective is to establish Internet-based energy services and test these within field trials in Sweden, Greece, the Czech Republic and the UK. The tasks include the prototyping and testing of energy services for citizens and professionals, and the establishment of cable and wireless approaches to Internet connection. The implementations are based on residential gateway, or 'e-box', technology. Users, for example utilities, citizens, local authority energy managers and health care providers, can access the information through standard Web browsers and, depending on the particular energy service, may transmit information or control requests back to the originating homes. This paper sets out the overall structure of the SmartHomes system and reports on progress to date

    Case studies of outdoor testing and analysis of building components

    Get PDF
    The construction and development of the PASSYS/PASLINK outdoor test cells were funded by the European Commission, with the objective of providing high-quality test environments for quantifying the performance of passive solar building components. Over the years since the original test cells were commissioned, the initial concept for outdoor testing has been extended to include other test cell types. Significant improvements have been made to the experimental procedures and analysis techniques, and a broad range of components has been tested. This paper describes representative experiments that have been conducted using these highly controlled outdoor test environments, indicates some of the related analysis, and shows the type of information that can be obtained from such tests. It demonstrates the way in which component performance can be ascertained in the realistic external environment. The case studies chosen range from building component tests within EC research projects to commercial tests, and from conventional building components to novel integrated facade systems. They also include a large range of passive and active components. Each case study summarises the test component, the purpose of the test, details of the test configuration (period of test, instrumentation, etc.), results and analysis, and associated modelling and monitoring where appropriate. The paper concludes with an appraisal of the advantages and limitations of the test cells for the various component types

    Integrated comparative validation tests as an aid for building simulation tool users and developers

    Get PDF
    Published validation tests developed within major research projects have been an invaluable aid to program developers to check on their programs. This paper sets out how selected ASHRAE Standard 140-2004 and European CEN standards validation tests have been incorporated into the ESP-r simulation program so that they can be easily run by users and also discusses some of the issues associated with compliance checking. Embedding the tests within a simulation program allows program developers to check routinely whether updates to the simulation program have led to significant changes in predictions and to run sensitivity tests to check on the impact of alternative algorithms. Importantly, it also allows other users to undertake the tests to check that their installation is correct and to give them, and their clients, confidence in results. This paper also argues that validation tests should characterize some of the significant heat transfer processes (particularly internal surface convection) in greater detail in order to reduce the acceptance bands for program predictions. This approach is preferred to one in which validation tests are overly prescriptive (e.g., specifying fixed internal convection coefficients), as these do not reflect how programs are used in practice

    Series of experiments for empirical validation of solar gain modelling in building energy simulation codes - experimental setup, test cell characterization, specifications and uncertainty analysis

    Get PDF
    Empirical validation of building energy simulation codes is an important component in understanding the capacity and limitations of the software. Within the framework of Task 34/Annex 43 of the International Energy Agency (IEA), a series of experiments was performed in an outdoor test cell. The objective of these experiments was to provide a high-quality data set for code developers and modelers to validate their solar gain models for windows with and without shading devices. A description of the necessary specifications for modeling these experiments is provided in this paper, which includes information about the test site location, experimental setup, geometrical and thermophysical cell properties including estimated uncertainties. Computed overall thermal cell properties were confirmed by conducting a steady-state experiment without solar gains. A transient experiment, also without solar gains, and corresponding simulations from four different building energy simulation codes showed that the provided specifications result in accurate thermal cell modeling. A good foundation for the following experiments with solar gains was therefore accomplished

    Empirical validation of models to compute solar irradiance on inclined surfaces for building energy simulation

    Get PDF
    Accurately computing solar irradiance on external facades is a prerequisite for reliably predicting thermal behavior and cooling loads of buildings. Validation of radiation models and algorithms implemented in building energy simulation codes is an essential endeavor for evaluating solar gain models. Seven solar radiation models implemented in four building energy simulation codes were investigated: (1) isotropic sky, (2) Klucher, (3) Hay-Davies, (4) Reindl, (5) Muneer, (6) 1987 Perez, and (7) 1990 Perez models. The building energy simulation codes included: EnergyPlus, DOE-2.1E, TRNSYS-TUD, and ESP-r. Solar radiation data from two 25 days periods in October and March/April, which included diverse atmospheric conditions and solar altitudes, measured on the EMPA campus in a suburban area in Duebendorf, Switzerland, were used for validation purposes. Two of the three measured components of solar irradiances - global horizontal, diffuse horizontal and direct-normal - were used as inputs for calculating global irradiance on a south-west façade. Numerous statistical parameters were employed to analyze hourly measured and predicted global vertical irradiances. Mean absolute differences for both periods were found to be: (1) 13.7% and 14.9% for the isotropic sky model, (2) 9.1% for the Hay-Davies model, (3) 9.4% for the Reindl model, (4) 7.6% for the Muneer model, (5) 13.2% for the Klucher model, (6) 9.0%, 7.7%, 6.6%, and 7.1% for the 1990 Perez models, and (7) 7.9% for the 1987 Perez model. Detailed sensitivity analyses using Monte Carlo and fitted effects for N-way factorial analyses were applied to assess how uncertainties in input parameters propagated through one of the building energy simulation codes and impacted the output parameter. The implications of deviations in computed solar irradiances on predicted thermal behavior and cooling load of buildings are discussed
    • …
    corecore